FTS14 ball float steam trap for stainless steel steam duties
Spirax Sarco FTS14 ball float steam traps provide continuous condensate drainage at steam temperature with integral air venting for stainless steel and hygienic steam duties.

Clean steam > Sanitary pressure reducing valves
Spirax Sarco SRV66 Sanitary Pressure Reducing Valve for Clean Steam Systems
SRV66 is a self-draining 316L sanitary pressure reducing valve for clean steam, water and inert gas duties where hygienic pipework needs local downstream pressure control without an external sensing line.
Quick facts
SRV66 is most useful where a hygienic process benefits from higher-pressure distribution upstream but lower and more stable pressure at the equipment connection. Typical examples include sterilising equipment, process vessels, humidifiers and other clean steam users that do not need main-line pressure at the point of use.
Installation guidance recommends treating SRV66 as part of a complete pressure reduction station. That usually means clean upstream separation and filtration, downstream overpressure protection where required, and separate isolation valves because the reducing valve is not intended to serve as the shut-off device.
That wider station logic is important on clean steam lines because pressure reduction affects not only process setpoint accuracy but also steam quality, condensate behaviour and the protection limits of downstream hygienic equipment.
Spirax Sarco FTS14 ball float steam traps provide continuous condensate drainage at steam temperature with integral air venting for stainless steel and hygienic steam duties.
Spirax Sarco CSF16 steam filters help remove contaminant particles from clean steam lines where steam quality, product contact and hygienic hardware protection matter.
CS10-1 is a 316L stainless steel clean steam separator for removing entrained moisture from clean and pure steam systems, with a removable baffle and electropolished internal finish.
BTM7 is a maintainable 316L thermostatic clean steam trap for hygienic condensate drainage where self-draining geometry and near-saturation discharge are required.
Sanitary pressure control is usually connected to wider clean steam quality, protection and process-control decisions.
Return to the wider clean steam range when sanitary pressure reduction is only one part of a broader hygienic steam system project.
Use clean service safety valves when downstream pressure reduction also needs dedicated overpressure protection.
Move into clean service control valves when the duty depends on modulating flow control rather than self-acting pressure reduction alone.